E absolute maximum ratings at 25°C free-air temperature (unless otherwise noted)†. Input-to-output peak voltage (8-ms half sine wave): 4N kV. standard single channel phototransistor couplers. These families include the 4N35, 4N36, 4N37, 4N38 couplers. Each optocoupler consists of. Cosmo 4n35 optoisolator for DC voltage measuring. Hi all, I’ve encountered a problem. I’ve tried to set the input current to the opto by using 5V.

Author: Barr Nilrajas
Country: Montenegro
Language: English (Spanish)
Genre: Literature
Published (Last): 5 October 2016
Pages: 491
PDF File Size: 16.92 Mb
ePub File Size: 14.81 Mb
ISBN: 587-5-77313-618-9
Downloads: 64140
Price: Free* [*Free Regsitration Required]
Uploader: Yogar

It will only work for input voltages high enough to turnt he LED on and it will be temperature sensitive though, so it is a very crude option. Turn on power triac – proposed circuit analysis 0.

Cosmo 4n35 optoisolator for DC voltage measuring I see. Digital multimeter appears to have measured voltages lower than expected. Distorted Sine output from Transformer 8. Opto 4n35 for voltage sensing?

Stepped down to 5V of course! A simple timer can convert the voltage to frequency is a cheaper alternate. I assume the phototransistor has a 1k collector load to 5V. Cosmo 4n35 optoisolator for DC voltage measuring Hurm Heat sinks, Part 2: The reason I wanted to put optoisolators because the project will interface with a 11kV switchgear. I guess there’s no substitute for the hcpl eh? Similar Threads use of a optoisolator in a power supply 4N35 fairchild 2. I don’t mind if the output voltage is not same as the input, but if it’s proportional, I can mend the voltage reading by inserting a constant in the microcontroller.

Cosmo 4n35 optoisolator for DC voltage measuring What voltage range are you trying to measure? The time now is How can the power consumption for computing be reduced for energy harvesting? AF modulator in Transmitter what is the A? Cosmo 4n35 optoisolator for DC voltage measuring If you have a high voltage available to drive the LED then the accuracy will improve although you will dissipate more power in the LED drive resistor.

  HISHAM SHARABI NEOPATRIARCHY PDF

In other words, plot the output voltage against input voltage and use the micro to correct for it.

PV charger battery circuit 4. Choosing IC with EN signal 2.

HOT NEW IC 4N35 F4N35 4N 35 COSMO SOP6

Equating complex number interms of the other 6. A crude option if you just want a rough voltage measurement would be to correct the measured value. So you circuit is working correctly – although maybe not how you want it to. Thanks Post added at How do you get an Fosmo design to market quickly? So, when you reduce the input voltage the LED current will reduce so the collector voltage will increase because the voltage drop in the 1k will reduce due to the reduced collector current.

Measuring air gap of a magnetic core for home-wound inductors and flyback transformer 7. Cosmo 4n35 optoisolator for DC voltage measuring Hi all, I’ve encountered a problem. Dec 248: I am not sure it would be much simpler than using a to turn it into a pulse train though.

HOT IC 4N35 F4N35 4N 35 COSMO DIP6

CMOS Technology file 1. I need to use 8 pieces lol. If that doesn’t make sense then maybe it will help to post your circuit, Keith. Cosmo 4n35 optoisolator for DC voltage measuring Yes, that is what I thought. Losses in inductor of a boost converter 9.

cosmo 4N35 datasheet & applicatoin notes – Datasheet Archive

Not only does it invert but the LED will be completely inoperative at low voltage and the linearity graph will look like a cross section of the Himalayas. Cosmo 4n35 optoisolator for DC voltage measuring Hi Keith, here is my circuit, Post added at Is the opto reverse biased? I think I will just let the ADC port get the signals directly from the contacts.

  COURS DE TURBOMACHINES PDF

ModelSim – How to force a struct type written in SystemVerilog? Part and Inventory Xosmo. Originally Posted by nandhu If you reduce the input voltage the output voltage will increase.

Cosmo 4n35 optoisolator codmo DC voltage measuring I can only guess at your circuit. How reliable is it? Dec 242: It would be useful to know what you are trying to measure – where the source voltage comes from.

Input port and input output port declaration in top module 2. Synthesized tuning, Part 2: Another option is to use a micro which has 8 adc inputs measure it and send it thro the opto. If you have a high voltage available to drive the LED then the accuracy will improve although you will dissipate more power in the LED drive resistor. Cosmo 4n35 optoisolator for DC voltage measuring What you have will be inversely proportional which would be fine – coosmo can be sorted out in software – except that if you were hoping to measure input voltage in that way you will fail because of the non-linear relationship between the LED current and voltage.